Network Working Group                                           R. Smith
Request for Comments: 1759                             Texas Instruments
Category: Standards Track                                      F. Wright
                                                   Lexmark International
                                                             T. Hastings
                                                       Xerox Corporation
                                                               S. Zilles
                                                     Adobe Systems, Inc.
                                                           J. Gyllenskog
                                                 Hewlett-Packard Company
                                                              March 1995

                              Printer MIB

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Table of Contents

   1. Introduction ................................................    3
   1.1 Network Printing Environment ...............................    3
   1.2 Printer Device Overview ....................................    4
   1.3 Categories of Printer Information ..........................    5
   1.3.1 Descriptions .............................................    5
   1.3.2 Status ...................................................    5
   1.3.3 Alerts ...................................................    5
   2. Printer Model ...............................................    6
   2.1 Overview of the Printer Model ..............................    8
   2.2 Printer Sub-Units ..........................................    8
   2.2.1 General Printer ..........................................    8
   2.2.2 Inputs ...................................................    9
   2.2.3 Media ....................................................    9
   2.2.4 Outputs ..................................................    9
   2.2.5 Finishers ................................................   10
   2.2.6 Markers ..................................................   10
   2.2.7 Media Paths ..............................................   11
   2.2.8 System Controller ........................................   11
   2.2.9 Interfaces ...............................................   11
   2.2.10 Channels ................................................   12
   2.2.11 Interpreters ............................................   12
   2.2.12 Console .................................................   12
   2.2.13 Alerts ..................................................   13
   2.2.13.1 Status and Alerts .....................................   13

   2.2.13.2 Overall Printer Status ................................   13
   2.2.13.2.1 Host MIB Printer Status .............................   15
   2.2.13.2.2 Sub-unit Status .....................................   17
   2.2.13.3 Alert Tables ..........................................   18
   2.2.13.4 Alert Table Management ................................   19
   2.3 Read-Write Objects .........................................   20
   2.4 Enumerations ...............................................   22
   2.4.1 Registering Additional Enumerated Values .................   22
   3. Objects from other MIB Specifications .......................   22
   3.1 System Group objects .......................................   22
   3.2 System Controller ..........................................   23
   3.3 Interface Group objects ....................................   23
   4. Textual Conventions .........................................   23
   5. The General Printer Group ...................................   27
   5.1 The Cover Table ............................................   30
   5.2 The Localization Table .....................................   31
   5.3 The System Resources Tables ................................   33
   6. The Responsible Party group .................................   35
   7. The Input Group .............................................   35
   8. The Extended Input Group ....................................   41
   9. The Input Media Group .......................................   42
   10. The Output Group ...........................................   44
   11. The Extended Output Group ..................................   48
   12. The Output Dimensions Group ................................   49
   13. The Output Features Group ..................................   51
   14. The Marker Group ...........................................   52
   15. The Marker Supplies Group ..................................   58
   16. The Marker Colorant Group ..................................   62
   17. The Media Path Group .......................................   64
   18. The Channel Group ..........................................   68
   18.1 The Channel Table and its underlying structure ............   69
   18.2 The Channel Table .........................................   70
   19. The Interpreter Group ......................................   73
   20. The Console Group ..........................................   81
   20.1 The Display Buffer Table ..................................   82
   20.2 The Console Light Table ...................................   83
   21. The Alerts Group ...........................................   85
   21.1 The Alert Time Group ......................................   92
   22. Appendix A - Glossary of Terms .............................   98
   23. Appendix B - Media Size Names ..............................  101
   24. Appendix C - Media Names ...................................  103
   25. Appendix D - Roles of Users ................................  107
   26. Appendix E - Participants ..................................  111
   27. Security Considerations ....................................  113
   28. Authors' Addresses .........................................  113

1.  Introduction

1.1.  Network Printing Environment

   The management of producing a printed document, in any computer
   environment, is a complex subject. Basically, the task can be divided
   into two overlapping pieces, the management of printing and the
   management of the printer. Printing encompasses the entire process of
   producing a printed document from generation of the file to be
   printed, selection of a printer, choosing printing properties,
   routing, queuing, resource management, scheduling, and final printing
   including notifying the user.  Most of the printing process is outside
   the scope of the model presented here; only the management of the
   printer is covered.

               Figure 1 - One Printer's View of the Network

    system   printer    asset     user          user           user
    manager  operator   manager
      O         O         O         O             O              O
     /|\       /|\       /|\       /|\           /|\            /|\
     / \       / \       / \       / \           / \            / \
      |         |         |         |             |              |
+---------+ +-------+ +-------+ +-------+   +-----------+ +-----------+
|configur-| |printer| | asset | |printer|   |   user    | |   user    |
|ator     | |manager| |manager| |browser|   |application| |application|
+---------+ +-------+ +-------+ +-------+   +-----------+ +-----------+
   ^            ^         ^         ^             |             |
   |R/W         |R/W      |R        |R      +-----------+ +-----------+
   |            |         |         |       |  spooler  | |  spooler  |
   |            |         |         |       +-----------+ +-----------+
   |            |         |         |             |             |
   |            |         |         |       +-----------+ +-----------+
   |            |         |         |       |supervisor | |supervisor |
   |            |         |         |       +-----------+ +-----------+
   |            |         |         |        ^       ^     ^       ^
   |            |         |         |        |R      |R/W  |R      |R/W
   v            v         |         |        |       |     |       |
==================================================   |   =====     |
                     |                          print|        print|
                     |SNMP                       data|         data|
  +-----+        +-------+                        PCL|          PCL|
  | MIB |<------>| agent |                 PostScript|   PostScript|
  +-----+        +-------+                       NPAP|         NPAP|
                     |unspecified                etc.|         etc.|
              +=============+  +-----------------+   |             |
              |             |--|channel/interface|<--+             |
              |             |  +-----------------+                 |
              |   PRINTER   |                                      |
              |             |  +-----------------+                 |
              |             |--|channel/interface|<----------------+
              +=============+  +-----------------+

1.2.  Printer Device Overview

   A printer is the physical device that takes media from an input
   source, produces marks on that media according to some page
   description or page control language and puts the result in some
   output destination, possibly with finishing applied. Printers are
   complex devices that consume supplies, produce waste and have
   mechanical problems. In the management of the physical printing
   device the description, status and alert information concerning the
   printer and its various subparts has to be made available to the

   management application so that it can be reported to the end user,
   key operators for the replenishment of supplies or the repair or
   maintenance of the device. The information needed in the management
   of the physical printer and the management of a printing job overlap
   highly and many of the tasks in each management area require the same
   or similar information.

1.3.  Categories of Printer Information

   Information about printers is classified into three basic categories,
   descriptions, status and alerts.

1.3.1.  Descriptions

   Descriptions convey information about the configuration and
   capabilities of the printer and its various sub-units. This
   information is largely static information and does not generally
   change during the operation of the system but may change as the
   printer is repaired, reconfigured or upgraded. The descriptions are
   one part of the visible state of the printer where state means the
   condition of being of the printer at any point in time.

1.3.2.  Status

   Status is the information regarding the current operating state of
   the printer and its various sub-units. Status is the rest of the
   visible state of the printer. As an example of the use of status, a
   management application must be able to determine if the various sub-
   units are ready to print or are in some state that prevents printing
   or may prevent printing in the future.

1.3.3.  Alerts

   An Alert is the representation of a reportable event in the printer.
   An event is a change in the state of the printer. Some of those state
   changes are of interest to a management application and are therefore
   reportable. Typically, these are the events that affect the printer's
   ability to print. Alerts usually occur asynchronously to the
   operation of the computer system(s) to which the printer is attached.
   For convenience below, "alert" will be used for both the event caused
   by a change in the printer's state and for the representation of that
   event.

   Alerts can be classified into two basic categories, critical and
   non-critical.  A critical alert is one that is triggered by entry
   into a state in which the printer is stopped and printing can not
   continue until the condition that caused critical alert is
   eliminated. "Out of paper", "toner empty" and "output bin full" are

   examples of critical alerts. Non-critical alerts are triggered by
   those events that enter a state in which printing is not stopped.
   Such a non-critical state may, at some future time, lead to a state
   in which printing may be stopped.  Examples of this kind of non-
   critical alerts are "input media low", "toner low" and "output bin
   nearly full". Or, a non-critical alert may simply provide
   information, such as signaling a configuration changed in the
   printer.

   Description, status and alert information about printer can be
   thought of as a data base describing the printer. The management
   application for a printer will want to view the printer data base
   differently depending on how and for what purposes the information in
   the data base is needed.

2.  Printer Model

   In order to accomplish the management of the printer, an abstract
   model of the printer is needed to represent the sub-units from which
   the printer is composed. A printer can be described as consisting of
   13 types of sub-units. It is important to note that the sub-units of
   a printer do not necessarily relate directly to any physically
   identifiable mechanism. Sub-units can also be a set of definable
   logical processes, such as interpreters for page description
   languages or command processors that set various operating modes of
   the printer.

   Figure 2 shows a block diagram of the printer and its basic 13 sub-
   units.

                     Figure 2 - Printer  Block Diagram

                           Physical Connections
                                   |
                                +-----------+
                                |           |
                            +-------------+ |
                            | Interface   |-+
                            | (RFC1213)   |
                            +-------------+
                                   |
                                +-----------+
                                |           |
                            +-------------+ |    +-----------+
                            | Channel     |-+    | Operator  |
                            |             |      |  Console  |
                            +-------------+      +-----------+
                                   |
                                +-----------+        +---------+
                                |           |        |         |
        +-----------+       +-------------+ |    +-----------+ |
        |  General  |       | Interpreter |-+    |  Alerts   |-+
        |  Printer  |       |             |      |           |
        +-----------+       +-------------+      +-----------+
                                   |
                   +-------------------------------+
                   |        System Controller      |
                   |     (This is the Host MIB)    |
                   +-------------------------------+

   +------+                    +--------+                  +--------+
   |      |                    |        |                  |        |
+-------+ |    +-------+    +---------+ |    +-------+   +--------+ |
| Input |-+  +--------+|    |  Marker |-+  +--------+|   | Output |-+
|       |===>|        |+<==>|         |<==>|        |+==>|        |
+-------+    +--+  +--+     +---------+    +--+  +--+    +--------+
   \            |  ||                         |  ||         \
    \           |  ||                         |  ||          \
     \          |  ||                         |  ||           \
    +--------+  |  |+-------------------------|  ||         +---------+
    |        |  |  +--------------------------+  ||         |         |
+----------+ |  |            Media Path          |+      +----------+ |
|  Media   |-+  +--------------------------------+       | Finisher |-+
|(optional)|                                             |(optional)|
+----------+                                             +----------+

2.1.  Overview of the Printer Model

   The model has three basic parts: (1) the flow of a print file into an
   interpreter and onto the marker, (2) the flow of media through the
   marker and (3) the auxiliary sub-units that control and facilitate
   the two prior flows.  The flow of the print data comes through a
   physical connection on which some form of transport protocol stack is
   running.  The data provided by the transport protocol (interface)
   appears on a channel which is the input to an interpreter. The
   interpreter converts the print data into a form suitable for marking
   on the media.

   The media resides in Input sub-units from which the media is selected
   and then transported via a Media Path first to a Marking sub-unit and
   then onto an Output sub-unit with (optionally) some finishing
   operations being performed.  The auxiliary sub-units facilitate
   control of the printer, inquiry/control of the operator panel,
   reporting of alerts, and the adaptation of the printer to various
   natural languages and characters sets. All the software sub-units run
   on the System Controller which represents the processor, memory and
   storage systems of the Printer.  Each of the sub-units is discussed
   in more detail below.

   All of the sub-units other than the Alerts report only state
   information, either a description or a status. The Alerts sub-unit
   reports event information.

2.2.  Printer Sub-Units

   A printer is composed of 13 types of sub-units, called groups.  The
   following sections describe the different types of sub-units.

2.2.1.  General Printer

   The general printer sub-unit is responsible for the overall control
   and status of the printer. There is exactly one general printer sub-
   unit in a printer. The general printer sub-unit is represented by the
   General Printer Group in the model. In addition to the providing the
   status of the whole printer and allowing the printer to be reset,
   this Group provides information on the status of the packaging of the
   printer, in particular, the covers. The general printer sub-unit is
   usually implemented on the system controller.

   The localization portion of the general printer sub-unit is
   responsible for identifying the natural language, country, and
   character set in which character strings are expressed. There may be
   one or more localizations supported per printer. The available
   localizations are represented by the Localization table.

   Localization is only performed on those strings in the MIB that are
   explicitely marked as being localized.  All other character strings
   are returned in ASCII.

   The character set portion of the general printer sub-unit is
   responsible for identifying the possible character sets that are used
   by the interpreters, the operator console, and in network management
   requests for display objects. There may be one or more character sets
   per printer.  The understood character sets are represented by the
   Character Set Table.

2.2.2.  Inputs

   Input sub-units are mechanisms that feed media to be marked on into
   the printer. A printer contains one or more input sub-units. These
   are represented by the Input Group in the model. The model does not
   distinguish fixed input bins from removable trays, except to report
   when a removable tray has been removed.

   There are as many input sub-units as there are distinctly selectable
   input "addresses".  For example, if a tray has an option for manually
   feeding paper as well as automatically feeding from the tray, then
   this is two input sub-units if these two sources can be (must be)
   separately selected and is one input sub-unit if putting a sheet in
   the manual feed slot overrides feeding from the contents of the tray;
   that is, in the second case there is no way to separately select or
   address the manual feed slot.

2.2.3.  Media

   An input sub-unit can hold one or more instances of the media on
   which marking is to be done. Typically, there is a large set of
   possible media that can be associated with an input. The Media Group
   is an extension of the Input Group which represents that media that
   is in an input sub-unit. The Media Group only describes the current
   contents of each input and not the possible content of the input
   sub-unit.

2.2.4.  Outputs

   Output sub-units are mechanisms that receive media that has been
   marked on. A printer contains one or more output mechanisms. These
   are represented by the Output Group in the model. The model does not
   distinguish fixed output bins from removable output bins, except to
   report when a removable bin has been removed.

   There are as many output sub-units as there are distinctly selectable
   output "addresses".  Output sub-units can be addressed in two

   different ways: (1) as a set of "mailboxes" which are addressed by a
   specific mailbox selector such as a bin number or a bin name, or (2)
   as a set of "slots" into which multiple copies are collated.
   Sometimes both modes of using the output sub-units can be used on the
   same printer.  All that is important from the viewpoint of the model
   is that the output units can be separately selected.

2.2.5.  Finishers

   A finisher is a sub-unit that performs some operations on the media
   other than marking.  The finisher sub-units are represented by the
   Finisher Group in the model.  Some examples of finishing processes
   are stapling, punching, binding, inserting, or folding.  Finishing
   processes may have supplies asssociated with the process.  Stapling,
   binding, and punching are examples of processes that have supplies. A
   printer may have more than one finishing sub-unit and each finishing
   sub-unit may be associated with one or more output sub-units.
   Finishers are not described in this MIB.

   The exact interaction and sequencing between an output device and its
   associated finisher is not specified by the model. It depends on the
   type of finishing process and the exact implementation of the printer
   system. This standard allows for the logical association of a
   finishing process with an output device but does not put any
   restrictions on the exact sequence or interaction with the associated
   output device. The output and finisher sub-units may or may not be
   separate identifiable physical mechanisms depending on the exact
   implementation of a printer.  In addition, a single output device may
   be associated with multiple finishing sub-units and a single
   finishing sub-unit may be associated with multiple output devices.

2.2.6.  Markers

   A marker is the mechanism that produces marks on the print media. The
   marker sub-units and their associated supplies are represented by the
   Marker Group in the model. A printer can contain one or more marking
   mechanisms.  Some examples of multiple marker sub-units are: a
   printer with separate markers for normal and magnetic ink or an
   imagesetter that can output to both a proofing device and final film.
   Each marking device can have its own set of  characteristics
   associated with it, such as marking technology and resolution.

   In this model the marker sub-unit is viewed as very generalized and
   encompasses all aspects of a marking process. For example, in a
   xero-graphic process, the marking process as well as the fusing
   process would be included in the generalized concept of the marker.
   With the generalized concept of a marking process, the concept of
   multiple marking supplies associated with a single marking sub-unit

   results. For example, in the xerographic process, there is not only a
   supply of toner, but there can also be other supplies such as a fuser
   supply that can be consumed and replaced separately. In addition
   there can be multiple supplies of toner for a single marker device,
   as in a color process.

2.2.7.  Media Paths

   The media paths encompass the mechanisms in the printer that move the
   media through the printer and connect all other media related sub-
   units: inputs, outputs, markers and finishers. A printer contains one
   or more media paths. These are represented by the Media Path Group in
   the model.  The Media Path group has some objects that apply to all
   paths plus a table of the separate media paths.

   In general, the design of the media paths determines the maximum
   speed of the printer as well as the maximum media size that the
   printer can handle. Media paths are complex mechanisms and can
   contain many different identifiable sub-mechanisms such as media
   movement devices, media buffers, duplexing units and interlocks. Not
   all of the various sub-mechanisms reside on every media path.  For
   example, one media path may provide printing only on one surface of
   the media (a simplex path) and another media path may have a sub-
   mechanism that turns the media over and feeds it a second time
   through the marker sub-unit (a duplex path).  The duplex path may
   even have a buffer sub-mechanism that allows multiple copies of the
   obverse side to be held before the reverse side of all the copies are
   marked.

2.2.8.  System Controller

   The System Controller is the sub-unit upon which the software
   components of the Printer run. The System Controller is represented
   in the model by the Host MIB. This MIB allows for the specification
   of the processor(s), memory, disk storage, file system and other
   underlying sub-mechanisms of the printer. The controller can range
   from simple single processor systems to multiprocessor systems. In
   addition, controllers can have a full range of resources such as hard
   disks. The printer is modeled to have one system controller even
   though it may have more than one processor and multiple other
   resources associated with it.

2.2.9.  Interfaces

   An interface is the communications port and associated protocols that
   are responsible for the transport of data to the printer. A printer
   has one or more interface sub-units. The interfaces are represented
   by the Interfaces Group of MIB-II (RFC 1213). Some examples of

   interfaces are serial ports (with little or no protocol) and EtherNet
   ports on which one might run InterNet IP, Novell IPX, etc.

2.2.10.  Channels

   The channel sub-units identify the independent sources of print data
   (here print data is the information that is used to construct printed
   pages and may have both data and control aspects).  A printer may
   have one or more channels. The channel sub-units are represented by
   the Channel Group in the Model. Each channel is typically identified
   by the electronic path and service protocol used to deliver print
   data to the printer. A channel sub-unit may be independently enabled
   (allowing print data to flow) or disabled (stopping the flow of print
   data). It has a current Control Language which can be used to specify
   which interpreter is to be used for the print data and to query and
   change environment variables used by the interpreters (and SNMP).
   There is also a default interpreter that is to be used if an
   interpreter is not explicitly specified using the Control Language.
   Channel sub-units are based on an underlying interface.

2.2.11.  Interpreters

   The interpreter sub-units are responsible for the conversion of a
   description of intended print instances into images that are to be
   marked on the media. A printer may have one or more interpreters. The
   interpreter sub-units are represented by the Interpreter Group in the
   Model. Each interpreter is generally implemented with software
   running on the System Controller sub-unit. The Interpreter Table has
   one entry per interpreter where the interpreters include both Page
   Description Language (PDL) Interpreters and Control Language
   Interpreters.

2.2.12.  Console

   Many printers have a console on the printer, the operator console,
   that is used to display and modify the state of the printer.  The
   console can be as simple as a few indicators and switches or as
   complicated as full screen displays and keyboards. There can be at
   most one such console.  This console sub-unit is represented by the
   Console Group in the model.  Although most of the information
   displayed there is also available in the state of the printer as
   represented by the various Groups, it is useful to be able to query
   and modify the operator console remotely.  For example, a management
   application might like to display to its user the current message on
   the operator console of the remote printer or the management
   application user might like to modify the current message on the
   operators console of the remote printer.  As another example, one
   might have a remote application that puts up a pseudo console on a

   workstation screen. Since the rules by which the printer state is
   mapped onto the console and vice versa are not standardized, it is
   not possible to reproduce the console state or the action of console
   buttons and menus. Therefore, the Console Group provides access to
   the console. The operator console is usually implemented on the
   system controller with additional hardware for input and display.

2.2.13.  Alerts

   The alert sub-unit is responsible for detecting reportable events,
   making an entry in the alert table and, if and only if the event is a
   critical event, initiating a trap. The alert sub-unit is represented
   by the Alerts Group and, in particular, the Alert Table. This table
   contains information on the severity, sub-unit, detailed location
   within the sub-unit, alert code and description of each critical
   alert that is currently active within the printer. Each reportable
   event causes an entry to be made in the Alert Table.

2.2.13.1.  Status and Alerts

   Summary information about the state of the printer is reported at
   three separate levels: (1) there is the status of the printer as a
   whole reported in the Host MIB, (2) there is the status of various
   sub-units reported in the principle table of the Group that
   represents the sub-unit, and (3) there are alert codes reported in
   the Alert Table.

2.2.13.2.  Overall Printer Status

   Of the many states a printer can be in, certain states are more
   "interesting" because of the distinct actions they are likely to
   provoke in the administrator.  These states may be applied to the
   printer as a whole, or to a particular sub-unit of the printer.
   These named states are:

   Non Critical Alert Active - For the printer this means that one or
   more sub-units have a non-critical alert active.  For a sub-unit,
   this means that the sub-unit has a non-critical alert active.

   Critical Alert Active - For the printer this means that one or more
   sub-units have a critical alert active.  For a sub-unit, this means
   that the sub-unit has a critical alert active.

   Unavailable - The printer or sub-unit is unavailable for use (this is
   the same as "broken" or "down" in other terminologies).  A trained
   service person is typically necessary to make it available.

   Busy / Temporarily Unavailable - The printer or sub-unit is
   operational but currently occupied with a request for activity. The
   sub-unit will become available without the need of human interaction.

   Moving on-line or off-line - The printer is either off-line, in the
   process of moving off-line or in the process of moving back on-line;
   for example on high end printers reloading paper involves a
   transition to off-line to open the paper bin, it is then filled and,
   finally, there is a transition back to on-line as the paper bin is
   repositioned for printing.

   Standby - The printer or sub-unit is unavailable for use because it
   is partially powered down and may need some period of time to become
   fully operational again.  A unit in Standby state shall respond to
   network management requests.

   The Host MIB provides three status objects that can be used to
   describe the status of a printer: (1) hrDeviceStatus in the entry in
   the Host MIB hrDeviceTable; (2) hrPrinterStatus in the
   hrPrinterTable; and (3) hrPrinterDetectedErrorState in the
   hrPrinterTable.  These objects describe many of the states that a
   printer can be in.  The following table shows how the "interesting"
   states named above can be recognized by inspecting the values of the
   three printer-related objects in the Host MIB:

Printer     hrDeviceStatus  hrPrinterStatus  hrPrinterDetectedErrorState
Status

Normal         running(2)     idle(3)        none set

Busy/          running(2)     printing(4)
Temporarily
Unavailable

Non Critical   warning(3)     idle(3) or     could be: lowPaper,
Alert Active                  printing(4)    lowToner, or
                                             serviceRequested

Critical       down(5)        other(1)       could be: jammed,
Alert Active                                 noPaper, noToner,
                                             coverOpen, or
                                             serviceRequested

Unavailable    down(5)        other(1)

Moving off-    warning(3)     idle(3) or     offline
line                          printing(4)

Off-line       down(5)        other(1)       offline

Moving         down(5)        warmup(5)
on-line

Standby        running(2)     other(1)

   These named states are only a subset of the possible states - they
   are not an exhaustive list of the possible states.  Nevertheless,
   several things should be noted.  When using these states, it is not
   possible to detect when both critical and non-critical alerts are
   pending - if both are pending, the Critical Alert Active state will
   prevail.  In addition, a printer in the Standby state will be
   represented in the Host MIB with a device status of running(2) and a
   printer status of other(1), a set of states that don't uniquely
   distinguish this important printer state.

   Although the above mapping is workable, it would be improved with a
   few additions to hrDeviceStatus and hrPrinterStatus in the Host
   Resources MIB. In particular, it would be appropriate to add a
   "standby" enumeration to hrDeviceStatus.  Similarly, it would be
   useful to add the following states to hrPrinterStatus: "offline" to
   indicate that reason for the printer being down (instead of having to
   use "other") which allows both "warning" and "offline" to indicate
   going offline and "down" and "offline" to indicate offline and
   "notApplicable" to cover cases, such as "standby", where the device
   state completely describes the state of the device.

   Detailed status per sub-unit is reported in the sub-unit status
   fields.

2.2.13.2.1.  Host MIB Printer Status

   For completeness, the definitions of the Printer Status objects of
   the Host MIB are given below:

      hrDeviceStatus OBJECT-TYPE
           SYNTAX  INTEGER {
                unknown(1),
                running(2),
                warning(3),
                testing(4),
                down(5)
           }
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                 "The current operational state of the device

                 described by this row of the table.  A value
                 unknown(1) indicates that the current state of the
                 device is unknown.  running(2) indicates that the
                 device is up and running and that no unusual error
                 conditions are known.  The warning(3) state
                 indicates that agent has been informed of an
                 unusual error condition by the operational software
                 (e.g., a disk device driver) but that the device is
                 still 'operational'.  An example would be high
                 number of soft errors on a disk.  A value of
                 testing(4), indicates that the device is not
                 available for use because it is in the testing
                 state.  The state of down(5) is used only when the
                 agent has been informed that the device is not
                 available for any use."
           ::= { hrDeviceEntry 5 }

   hrPrinterStatus OBJECT-TYPE
          SYNTAX INTEGER {
              other(1),
              unknown(2),
              idle(3),
              printing(4),
              warmup(5)
          }
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
                  "The current status of this printer device.  When
                  in the idle(1), printing(2), or warmup(3) state,
                  the corresponding hrDeviceStatus should be
                  running(2) or warning(3).  When in the unknown
                  state, the corresponding hrDeviceStatus should be
                  unknown(1)."
          ::= { hrPrinterEntry 1 }

      hrPrinterDetectedErrorState OBJECT-TYPE
          SYNTAX OCTET STRING
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
                  "This object represents any error conditions
                  detected by the printer.  The error conditions are
                  encoded as bits in an octet string, with the
                  following definitions:

                       Condition         Bit #    hrDeviceStatus

                       lowPaper          0        warning(3)
                       noPaper           1        down(5)
                       lowToner          2        warning(3)
                       noToner           3        down(5)
                       doorOpen          4        down(5)
                       jammed            5        down(5)
                       offline           6        down(5)
                       serviceRequested  7        warning(3)

                  If multiple conditions are currently detected and
                  the hrDeviceStatus would not otherwise be
                  unknown(1) or testing(4), the hrDeviceStatus shall
                  correspond to the worst state of those indicated,
                  where down(5) is worse than warning(3) which is
                  worse than running(2).

                  Bits are numbered starting with the most
                  significant bit of the first byte being bit 0, the
                  least significant bit of the first byte being bit
                  7, the most significant bit of the second byte
                  being bit 8, and so on.  A one bit encodes that
                  the condition was detected, while a zero bit
                  encodes that the condition was not detected.

                  This object is useful for alerting an operator to
                  specific warning or error conditions that may
                  occur, especially those requiring human
                  intervention."
          ::= { hrPrinterEntry 2 }

2.2.13.2.2.  Sub-unit Status

   Sub-unit status is reported in the entries of the principle table in
   the Group that represents the sub-unit. For sub-units that report a
   status, there is a status column in the table and the value of this
   column is always an integer formed in the following way.

   The SubUnitStatus is an integer that is the sum of 5 distinct values,
   Availability, Non-Critical, Critical, On-line, and Transitioning.
   These values are:

     Availability                           value

            Available and Idle              0       000'b
            Available and Standby           2       010'b
            Available and Active            4       100'b
            Available and Busy              6       110'b
            Unavailable and OnRequest       1       001'b

            Unavailable because Broken      3       011'b
            Unknown                         5       101'b

    Non-Critical

            No Non-Critical Alerts          0
            Non-Critical Alerts             8

    Critical

            No Critical Alerts              0
            Critical Alerts                 16

    On-Line

            Intended state is On-Line       0
            Intended state is Off-Line      32

    Transitioning

            At intended state               0
            Transitioning to intended state 64

   For example, an input (tray) that jammed on the next to the last page
   may show a status of 27 (unavailable because broken (3) + a critical
   state (16), jammed, and a noncritical state (8), low paper).

2.2.13.3.  Alert Tables

   The Alert Group consists of a single table in which all active alerts
   are represented.  This section provides and overview of the table and
   a description of how it is managed.  The basic content of the alert
   table is the severity (critical or non-critical) of the alert, the
   Group and entry where a state change caused the alert, additional
   information about the alert (a more detailed location, an alert code,
   and a description), and an indication of the level of training needed
   to service the alert.

   The Alert Table contains some information that is redundant, for
   example that an event has occurred, and some information that is only
   represented in the Alert Table, for example the additional
   information.  A single table was used because a single entry in a
   Group could cause more than one alert, for example paper jams in more
   than one place in a media path. Associating the additional
   information with the entry in the affected group would only allow one
   report where associating the additional information with the alert
   makes multiple reports possible.

   Every time an alert occurs in the printer, the printer makes one or
   more entries into the Alert Table. The printer determines if an event
   is to be classified as critical or non-critical. If the severity of
   the Alert is "critical", the printer sends a trap or event
   notification to the host indicating that the table has changed.
   Whether or not a trap is sent, the management application is expected
   to poll the printer on a regular basis and to read and parse the
   table to determine what conditions have changed, in order to provide
   reliable information to the management application user.

2.2.13.4.  Alert Table Management

   The alert tables are sparsely populated tables. This means the tables
   will only contain entries of the alerts that are currently active and
   the number of rows, or entries in the table will be dynamic. More
   than one event can be added or removed from the event tables at a
   time depending on the implementation of the printer.

   There are basically two kinds of events that produce alerts: binary
   change events and simple change events. Binary change events come in
   pairs: the leading edge event and the trailing edge event. The
   leading edge event enters a state from which there is only one exit;
   for example, going from running to stopped with a paper jam. The only
   exit from this state is fixing the paper jam and it is clear when
   that is accomplished.  The trailing edge event is the event which
   exits the state the was entered by the leading edge event; in the
   example above fixing the paper jam is the trailing edge event.

   It is relatively straightforward to manage binary change events in
   the Alert Table. Only the leading edge event makes an entry in the
   alert table.  This entry persists in the Alert Table until the
   trailing edge event occurs at which point this event is signal by the
   removal of the leading edge event entry in the Alert Table.  That is,
   a trailing edge event does not create an entry; it removes the
   corresponding leading edge event. With binary events it is possible
   to compute the maximum number that can occur at the same time and
   construct an Alert Table that would hold that many events. There
   would be no possibility of table overflow and no information about
   outstanding events would be lost.

   Unfortunately, there are some events that are not binary changes.
   This other category of event, the simple change event,  is
   illustrated by the configuration change event. With this kind of
   event the state of the machine has changed, but to a state which is
   (often) just as valid as the state that was left and from which no
   return is necessary.  For example, an operator may change the paper
   that is in the primary input source from letter to legal. At some
   time in the future the paper may be changed back to letter, but it

   might be changed to executive instead.  This is where the problem
   occurs. It is not obvious how long to keep simple change event
   entries in the Alert Table. It they were never removed, the Alert
   Table would continue to grow indefinitely.

   The agent needs to have an algorithm implemented for the management
   of the alert table, especially in the face of combinations of binary
   and simple alerts that would overflow the storage capaciity of the
   table.  When the table is full and a new alert needs to be added, an
   old alert needs to be deleted.  The alert to be deleted should be
   chosen using the following rules:

    1. Find a non-critical simple alert and delete it.  If there are
       multiple non-critical simple alerts, it is suggested that the
       oldest one be chosen.  If there are no non-critical simple
       alerts, then,

    2. Find a non-critical binary alert and delete it.  If there are
       multiple non-critical binary alerts, it is suggested that the
       oldest one be chosen.  If there are no non-critical binary
       alerts, then,

    3. Find a critical (binary) alert and delete it.  If there are
       multiple critical alerts, it is suggested that the
       oldest one be chosen.  Agent implementors are encouraged to
       provide at least enough storage space for the maximum number
       of critical alerts that could occur simultaneously.  Note that
       all critical alerts are binary.

   Note that because the Alert Index is a monotonically increasing
   integer there will be gaps in the values in the table when an alert
   is deleted.  Such gaps can be detected by the management application
   to indicate that the management application may want to re-acquire
   the Printer state and check for state changes it did not observe in
   the Alert Table.

2.3.  Read-Write Objects

   Some of the objects in the printer MIB report on the existence of or
   amount of a given resource used with the printer.  Some examples of
   such resources are the size and number of sheets of paper in a paper
   tray or the existence of certain output options.  On some printers
   there are sensors that allow these resources to be sensed.  Other
   printers, however, lack sensors that can detect (all of) the
   properties of the resource.  Because the printer needs to know of the
   existence or properties of these resources for the printer to
   function properly some other way of providing this information is
   needed.  The chosen way to solve this problem is to allow a

   management application to write into objects which hold the
   descriptive or existence values for printers that cannot sense the
   values.  Thus many of the objects in the MIB are given read-write
   access, but a printer implementation might only permit a management
   operation to change the value if the printer could not sense the
   value itself.  Therefore, the ability to change the value of a read-
   write object may depend on the implementation of the agent.  Note
   that even though some objects explicitely state the behaviour of
   conditional ability to change values, any read-write object may act
   that way.

   Generally, an object is given read-write access in the Printer MIB
   specification if:

  1.The object involves installation of a resource that some
    printers cannot themselves detect.  Therefore, external means are
    needed to inform the printer of the installation.  (Here external
    means include using the operator console, or remote management
    application) and

  2.The printer will behave differently if the installation of the
    resource is reported than the printer would if the installation
    were not reported; that is, the object is not to be used
    as a place to put information not used by the printer, i.e., not a
    "PostIt".  Another way of saying this is that the printer believes
    that information given it and acts as if the information were
    true.  For example, on a printer that cannot sense the size, if
    one paper size is loaded, but another size is set into the paper
    size object, then the printer will use the size that was
    set as its current paper size in its imaging and paper handling.

   The printer may get hints that it may not know about the existence or
   properties of certain resources.  For example, a paper tray may be
   removed and re-inserted.  When this removal and insertion happens,
   the printer may either assume that a property, such as the size of
   paper in the tray, has not changed or the printer may change the
   value of the associated object to "unknown", as might be done for the
   amount of paper in the tray.  As long as the printer acts according
   to the value in  the object either strategy is acceptable.

   It is an implementation-specific matter as to whether or not MIB
   object values are persistent across power cycles or cold starts.  It
   is particularly important that the values of the prtMarkerLifeCount
   object persist throughout the lifetime of the printer.  Therefore, if
   the value of any MIB object persists across power cycles, then the
   prtMarkerLifeCount object must also persist.

2.4.  Enumerations

   Enumerations (enums) are sets of symbolic values defined for use with
   one or more objects.  Some common enumeration sets are assigned a
   symbolic data type name (textual convention).  These enumerations are
   listed at the beginning of this specification.

2.4.1.  Registering Additional Enumerated Values

   This working group has defined several type of enumerations.  These
   enumerations differ in the method employed to control the addition of
   new enumerations.  Throughout this document, references to
   "enumeration (n)", where n can be 1, 2 or 3 can be found in the
   various tables.  The definitions of these types of enumerations are:

  enumeration (1)  All the values are defined in the Printer MIB
     specification (RFC for the Printer MIB).  Additional enumerated
     values require a new RFC.

  enumeration (2)  An initial set of values are defined in the Printer
     MIB specification.  Additional enumerated values are
     registered after review by this working group. The initial
     versions of the MIB will contain the values registered so far.
     After the MIB is approved, additional values will be
     registered through IANA after approval by this working group.

  enumeration (3)  An initial set of values are defined in the Printer
     MIB specification.  Additional enumerated values are
     registered without working group review.  The initial versions of
     the MIB will contain the values registered so far.  After the MIB
     is approved, additional values will be registered
     through IANA without approval by this working group.

3.  Objects from other MIB Specifications

   This section lists the objects from other IETF MIB specifications
   that are mandatory for conformance to this Printer MIB specification.

3.1.  System Group objects

   All objects in the system group of MIB-II (RFC 1213) must be
   implemented.

3.2.  System Controller

   The System Controller is represented by the Storage and Device Groups
   of the Host Resources MIB (RFC 1514).  These are the only groups that
   are required to be implemented.  Other Groups (System, Running
   Software, Running Software Performance, and Installed Software) may
   be implemented at the discretion of the implementor.

3.3.  Interface Group objects

   All objects in the Interfaces Group of MIB-II (RFC 1213) shall be
   implemented.

Printer-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, experimental, Counter32, Integer32,
        TimeTicks, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
    TEXTUAL-CONVENTION FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
    hrDeviceIndex, hrStorageIndex FROM HOST-RESOURCES-MIB;

printmib MODULE-IDENTITY
    LAST-UPDATED "9411250000Z"
    ORGANIZATION "IETF Printer MIB Working Group"
    CONTACT-INFO
            "        Steven Waldbusser
         Postal: Carnegie Mellon University
                     4910 Forbes Ave
                  Pittsburgh, PA, 15213

                Tel: 412-268-6628
                Fax: 412-268-4987
             E-mail: waldbusser@cmu.edu"
    DESCRIPTION
            "The MIB module for management of printers."
    ::= { mib-2 43 }

-- Textual conventions for this MIB module

MediaUnit ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Units of measure for media dimensions."
    -- This is a type 1 enumeration.
    SYNTAX       INTEGER {
                     tenThousandthsOfInches(3),  -- .0001
                     micrometers(4)

                 }

CapacityUnit ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Units of measure for media capacity."
    -- This is a type 1 enumeration.
    SYNTAX       INTEGER {
                     tenThousandthsOfInches(3),  -- .0001
                     micrometers(4),
                     sheets(8),
                     feet(16),
                     meters(17)
                 }

SubUnitStatus ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Status of a printer sub-unit.

             The SubUnitStatus is an integer that is the sum of 5
             distinct values, Availability, Non-Critical, Critical,
             On-line, and Transitioning. These values are:

     Availability                           value

            Available and Idle              0       000'b
            Available and Standby           2       010'b
            Available and Active            4       100'b
            Available and Busy              6       110'b
            Unavailable and OnRequest       1       001'b
            Unavailable because Broken      3       011'b
            Unknown                         5       101'b

    Non-Critical

            No Non-Critical Alerts          0
            Non-Critical Alerts             8

    Critical

            No Critical Alerts              0
            Critical Alerts                 16

    On-Line

            Intended state is On-Line       0
            Intended state is Off-Line      32

    Transitioning

            At intended state               0
            Transitioning to intended state 64
    "

    SYNTAX       INTEGER (0..126)

PresentOnOff ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Presence and configuration of a device or feature."
    -- This is a type 1 enumeration.
    SYNTAX       INTEGER {
                     other(1),
                     on(3),
                     off(4),
                     notPresent(5)
                 }

  CodedCharSet ::= TEXTUAL-CONVENTION
      STATUS     current
      DESCRIPTION
         "A coded character set value that specifies both a set of
          characters that may be used and an encoding (as one or more
          octets) that is used to represent the characters in the
          set. These values are to be used to identify the encoding
          employed for strings in the MIB where this is not fixed by
          the MIB.

          Some objects that allow a choice of coded character set
          are: the prtLocalizationCharacterSet object in the
          LocalizationTable and prtInterpreterDefaultCharSetIn.
          The prtGeneralCurrentLocalization and prtConsoleLocalization
          objects in turn contain the index in the LocalizationTable
          of the current localization (country, language, and coded
          character set) of the `description' objects and the console,
          respectively.

          The space of the coded character set enumeration has been
          divide into three regions. The first region (3-999) consists
          of coded character sets that have been standardized by some
          standard setting organization. This region is intended for
          standards that do not have subset implementations. The
          second region (1000-1999) is for the Unicode and ISO/IEC 10646
          coded character sets together with a specification of a (set
          of) sub-repetoires that may occur.  The third region (>1999)
          is intended for vendor specific coded character sets.

          NOTE: Unicode and ISO 10646 character coded data may be
          processed and stored in either Big Endian (most significant
          octet first) or Little Endian (least significant octet
          first) order.  Intel x86, VAX, and Alpha/AXP architectures are
          examples of Little Endian processor architectures.
          Furthermore, in environments where either order may occur,
          so-called Unicode BYTE ORDER MARK (BOM) character (which is
          ISO 10646 ZERO WIDTH NO BREAK SPACE), coded as FEFF in two
          octets and 0000FEFF in four octets is used at the beginning
          of the data as a signature to indicate the order of the
          following data (See ISO 10646 Annex F).  Thus either
          ordering and BOM may occur in print data streams sent to the
          interpreter.  However, ISO 8824/8825 (ASN.1/BER) used by
          SNMP is quite clear that Big Endian order shall be used and
          BOM shall NOT be used in transmission in the protocol.
          Transmitting Unicode in Big Endian order in SNMP should
          not prove to be a hardship for Little Endian machines,
          since SNMP ASN.1/BER requires integers to be transmitted
          in Big Endian order as well.  So SNMP implementations on
          Little Endian machines are already reversing the order of
          integers to make them Big Endian for transmission via
          SNMP.  Also Unicode characters are usually treated as
          two-octet integers, not short text strings, so that it will
          be straightforward for Little Endian machines to reverse the
          order of Unicode character octets as well before
          transmitting them and after receiving them via the SNMP
          protocol.

          Where a given coded character set may be known by more than
          one name, the most commonly known name is used as the name
          of the enumeration and other names are shown in the
          comments.  The comments also indicate where to find detailed
          information on the coded character set and briefly
          characterize its relationship to other similar coded
          character sets.

          The current list of character sets and their enumerated
          values used to reference them is contained in the IANA
          Character Set registry.  The enum value is indicated by
          the MIBenum entry in the registry.  The enum symbol is
          indicated by the Alias that starts with `cs' for character
          set.

          The IANA character sets registry is available via
          anonymous ftp.

          The ftp server is ftp.isi.edu.
          The subdirectory is /in-notes/iana/assignments/.

          The file name is character-sets.

          To add a character set to the IANA Registry:

             1. Format an entry like those in the current list,
                omitting the MIBenum value.
             2. Send the entry with a request to add the entry
                to the character set list to iana@ISI.EDU.
             3. The IANA will supply a unique MIBenum value
                and update the list."

      -- This is a type 3 enumeration.

      SYNTAX     INTEGER {
        other(1)               -- used if the designated coded
                               -- character set is not currently in
                               -- the enumeration

      -- See IANA Registry for standard character sets in the
      -- MIBenum range of 3-999.

      -- See IANA Registry for Unicode and vendor-supplied
      -- combinations of ISO collections and character sets based
      -- on Unicode in the MIBenum range of 1000-1999.
      -- See IANA Registry for vendor developed character sets
      -- in the MIBenum range of 2000-xxxx.
   }

-- The General Printer Group
--
-- The general printer sub-unit is responsible for the overall control
-- and status of the printer.  There is exactly one general printer
-- sub-unit in a printer.
--
-- Implementation of every object in this group is mandatory.

prtGeneral  OBJECT IDENTIFIER ::= { printmib 5 }

prtGeneralTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtGeneralEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of general information per printer.
        Objects in this table are defined in various
        places in the MIB, nearby the groups to
        which they apply.  They are all defined

        here to minimize the number of tables that would
        otherwise need to exist."
    ::= { prtGeneral 1 }

prtGeneralEntry OBJECT-TYPE
    SYNTAX      PrtGeneralEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry exists in this table for each
        device entry in the hostmib device table who's type
        is `printer'"
    INDEX  { hrDeviceIndex }
    ::= { prtGeneralTable 1 }

PrtGeneralEntry ::= SEQUENCE {
    -- Note that not all of the objects in this sequence are in the
    -- general printer group.
    prtGeneralConfigChanges         Counter32,
    prtGeneralCurrentLocalization   Integer32,
    prtGeneralReset                 INTEGER,
    prtGeneralCurrentOperator       OCTET STRING,
    prtGeneralServicePerson         OCTET STRING,
    prtInputDefaultIndex            Integer32,
    prtOutputDefaultIndex           Integer32,
    prtMarkerDefaultIndex           Integer32,
    prtMediaPathDefaultIndex        Integer32,
    prtConsoleLocalization          Integer32,
    prtConsoleNumberOfDisplayLines  Integer32,
    prtConsoleNumberOfDisplayChars  Integer32,
    prtConsoleDisable               INTEGER
}

prtGeneralConfigChanges OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "Counts configuration changes that change the capabilities of
        a printer, such as the addition/deletion of input/output bins,
        the addition/deletion of interpreters, or changes in media
        size.  Such changes will often affect the capability of the
        printer to service certain types of print jobs.

        Management applications may cache infrequently changed
        configuration  information about sub-units on the printer.
        This object should be incremented whenever the agent wishes
        such applications to invalidate that cache and re-download

        all of this configuration information, thereby signalling a
        change in the printer's configuration.

        For example, if an input tray that contained paper of
        different dimensions was added, this counter would be
        incremented.

        As an additional example, this counter would not be
        incremented when an input tray is removed or the level of an
        input device changes."
    ::= { prtGeneralEntry 1 }

prtGeneralCurrentLocalization OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The value of the prtLocalizationIndex corresponding to the
        current language, country, and character set to be used for
        localized string values that are identified as being dependent
        on the value of this object.  Note that this object does not
        apply to localized strings in the prtConsole group or any
        object that is not identified as above."
    ::= { prtGeneralEntry 2 }

prtGeneralReset OBJECT-TYPE
    -- This value is a type 3 enumeration
    SYNTAX     INTEGER {
                   notResetting(3),
                   powerCycleReset(4), -- Cold Start
                   resetToNVRAM(5), -- Warm Start
                   resetToFactoryDefaults(6) -- Reset contents of
                                             -- NVRAM to factory defaults
               }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "Setting this value to `powerCycleReset', `resetToNVRAM', or
        `resetToFactoryDefaults' will result in the resetting of the
        printer.  When read, this object will always have the value
        `notResetting(3)', and a SET of the value `notResetting' shall
        have no effect on the printer.  Some of the defined values are
        optional.  However, every implementation must support at least
        the values `notResetting' and resetToNVRAM'."
    ::= { prtGeneralEntry 3 }

-- The Cover Table
--
-- The cover portion of the General print sub-unit describes the
-- covers and interlocks of the printer.  The Cover Table has an
-- entry for each cover and interlock.

prtCover    OBJECT IDENTIFIER ::= { printmib 6 }

prtCoverTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtCoverEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of the covers and interlocks of the printer."
    ::= { prtCover 1 }

prtCoverEntry OBJECT-TYPE
    SYNTAX     PrtCoverEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Information about a cover or interlock.
        Entries may exist in the table for each device
        index whose device type is `printer'."
    INDEX  { hrDeviceIndex, prtCoverIndex }
    ::= { prtCoverTable 1 }

PrtCoverEntry ::= SEQUENCE {
    prtCoverIndex            Integer32,
    prtCoverDescription      OCTET STRING,
    prtCoverStatus           INTEGER
}

prtCoverIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this Cover
        sub-unit.  Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new
        cover sub-units to the printer), values are expected to
        remain stable across successive printer power cycles."
    ::= { prtCoverEntry 1 }

prtCoverDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only

    STATUS     current
    DESCRIPTION
        "The manufacturer provided cover sub-mechanism  name in the
        localization specified by prtGeneralCurrentLocalization."
    ::= { prtCoverEntry 2 }

prtCoverStatus  OBJECT-TYPE
    --  This value is a type 2 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   doorOpen(3),
                   doorClosed(4),
                   interlockOpen(5),
                   interlockClosed(6)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The status of this cover sub-unit."
    ::= { prtCoverEntry 3 }

-- The Localization Table
--

-- The localization portion of the General printer sub-unit is

-- responsible for identifying the natural language, country, and
-- character set in which character strings are expressed. There
-- may be one or more localizations supported per printer. The
-- available localizations are represented by the Localization table.

prtLocalization  OBJECT IDENTIFIER ::= { printmib 7 }

prtLocalizationTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtLocalizationEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "The available localizations in this printer."
    ::= { prtLocalization 1 }

prtLocalizationEntry OBJECT-TYPE
    SYNTAX     PrtLocalizationEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A description of a localization.

        Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtLocalizationIndex }
    ::= { prtLocalizationTable 1 }

PrtLocalizationEntry ::= SEQUENCE {
        prtLocalizationIndex                Integer32,
        prtLocalizationLanguage             OCTET STRING,
        prtLocalizationCountry              OCTET STRING,
        prtLocalizationCharacterSet         CodedCharSet
}

prtLocalizationIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this
        localization entry.  Although these values may change due to a
        major reconfiguration of the device (e.g., the addition of new
        Cover sub-units to the printer), values are expected to remain
        stable across successive printer power cycles."
    ::= { prtLocalizationEntry 1 }

prtLocalizationLanguage OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..2))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "A two character language code from ISO 639.  Examples EN, GB,
        CA, FR, DE."
    ::= { prtLocalizationEntry 2 }

prtLocalizationCountry OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..2))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "A two character country code from ISO 3166, a blank string
        (two space characters) shall indicate that the country is
        not defined.  Examples: US, FR, DE, ..."
    ::= { prtLocalizationEntry 3 }

prtLocalizationCharacterSet OBJECT-TYPE
    SYNTAX     CodedCharSet
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION

        "The coded character set used for this localization."
    ::= { prtLocalizationEntry 4 }

-- The System Resources Tables

-- The Printer MIB makes use of the Host MIB to
-- define system resources by referencing the storage
-- and device groups of the print group.  In order to
-- determine, amongst multiple printers serviced by
-- one agent, which printer owns a particular
-- resource, the prtStorageRef and prtDeviceRef tables
-- associate particular storage and device entries to
-- printers.

prtStorageRefTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtStorageRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtGeneral 2 }

prtStorageRefEntry OBJECT-TYPE
    SYNTAX     PrtStorageRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "This table will have an entry for each entry in
        the host MIB storage table that represents storage associated
        with a printer managed by this agent."
    INDEX      { hrStorageIndex, prtStorageRefSeqNumber }
    ::= { prtStorageRefTable 1 }

PrtStorageRefEntry ::= SEQUENCE {
    prtStorageRefSeqNumber  Integer32,
    prtStorageRefIndex      Integer32
}

prtStorageRefSeqNumber OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "This value will be unique amongst all entries with a common
        value of hrStorageIndex.

        This object allows a storage entry to point to the multiple
        printer devices with which it is associated."

    ::= { prtStorageRefEntry 1 }

prtStorageRefIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of the hrDeviceIndex of the printer device that this
        storageEntry is associated with."
    ::= { prtStorageRefEntry 2 }

prtDeviceRefTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtDeviceRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtGeneral 3 }

prtDeviceRefEntry OBJECT-TYPE
    SYNTAX     PrtDeviceRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "This table will have an entry for each entry in
        the host MIB device table that represents a device associated
        with a printer managed by this agent."
    INDEX      { hrDeviceIndex, prtDeviceRefSeqNumber }
    ::= { prtDeviceRefTable 1 }

PrtDeviceRefEntry ::= SEQUENCE {
    prtDeviceRefSeqNumber   Integer32,
    prtDeviceRefIndex       Integer32
}

prtDeviceRefSeqNumber OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "This value will be unique amongst all entries with a common
        value of hrDeviceIndex.

        This object allows a device entry to point to the multiple
        printer devices with which it is associated."
    ::= { prtDeviceRefEntry 1 }

prtDeviceRefIndex OBJECT-TYPE

    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of the hrDeviceIndex of the printer device that this
        deviceEntry is associated with."
    ::= { prtDeviceRefEntry 2 }

-- The Responsible Party group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtGeneralCurrentOperator OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..127))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name of the current human operator responsible for
        operating this printer. It is suggested that this string
        include information that would enable other humans to reach
        the operator, such as a phone number."
    ::= { prtGeneralEntry 4 }

prtGeneralServicePerson OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..127))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name of the last human responsible for servicing
        this printer. It is suggested that this string
        include information that would enable other humans to reach
        the service person, such as a phone number."
    ::= { prtGeneralEntry 5 }

-- The Input Group
--
-- Input sub-units are managed as a tabular, indexed collection of
-- possible devices capable of providing media for input to the printing
-- process.  Input sub-units typically have a location, a type, an
-- identifier, a set of constraints on possible media sizes and
-- potentially other media characteristics, and may be capable of
-- indicating current status or capacity.
--
-- Implementation of every object in this group is mandatory.

prtInput   OBJECT IDENTIFIER ::= { printmib 8 }

prtInputDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
       "The value of prtInputIndex corresponding to the default input
        sub-unit: that is, this object selects the default source of
        input media."
    ::= { prtGeneralEntry 6 }

prtInputTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtInputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of the devices capable of providing media for input
        to the printing process."
    ::= { prtInput 2 }

prtInputEntry OBJECT-TYPE
    SYNTAX     PrtInputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Attributes of a device capable of providing media for input
        to the printing process.

        Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtInputIndex }
    ::= { prtInputTable 1 }

PrtInputEntry ::= SEQUENCE {
        prtInputIndex                     Integer32,
        prtInputType                      INTEGER,
        prtInputDimUnit                   MediaUnit,
        prtInputMediaDimFeedDirDeclared   Integer32,
        prtInputMediaDimXFeedDirDeclared  Integer32,
        prtInputMediaDimFeedDirChosen     Integer32,
        prtInputMediaDimXFeedDirChosen    Integer32,
        prtInputCapacityUnit              CapacityUnit,
        prtInputMaxCapacity               Integer32,
        prtInputCurrentLevel              Integer32,
        prtInputStatus                    SubUnitStatus,
        prtInputMediaName                 OCTET STRING,
        prtInputName                      OCTET STRING,
        prtInputVendorName                OCTET STRING,
        prtInputModel                     OCTET STRING,

        prtInputVersion                   OCTET STRING,
        prtInputSerialNumber              OCTET STRING,
        prtInputDescription               OCTET STRING,
        prtInputSecurity                  PresentOnOff,
        prtInputMediaWeight               Integer32,
        prtInputMediaType                 OCTET STRING,
        prtInputMediaColor                OCTET STRING,
        prtInputMediaFormParts            Integer32
}

prtInputIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this input
        sub-unit. Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new
        input sub-units to the printer), values are expected to
        remain stable across successive printer power cycles."
    ::= { prtInputEntry 1 }

prtInputType OBJECT-TYPE
    --  This value is a type 2 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   sheetFeedAutoRemovableTray(3),
                   sheetFeedAutoNonRemovableTray(4),
                   sheetFeedManual(5),
                   continuousRoll(6),
                   continuousFanFold(7)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of technology (discriminated primarily according to
        feeder mechanism type) employed by the input sub-unit.  Note,
        the Optional Input Class provides for a descriptor field to
        further qualify the other choice."
    ::= { prtInputEntry 2 }

prtInputDimUnit OBJECT-TYPE
    SYNTAX     MediaUnit
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measurement for use calculating and relaying

        dimensional values for this input sub-unit."
    ::= { prtInputEntry 3 }

prtInputMediaDimFeedDirDeclared OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "This object provides the value of the declared dimension, in
        the feed direction, of the media that is (or, if empty, was or
        will be) in this input sub-unit.  The feed direction is the
        direction in which the media is fed on this sub-unit.  This
        dimension is measured in input sub-unit dimensional units
        (prtInputDimUnit).  If this input sub-unit can reliably sense
        this value, the value is sensed by the printer and may not be
        changed by management requests.  Otherwise, the value may be
        changed. The value (-1) means other and specifically means
        that this sub-unit places no restriction on this parameter.
        The value (-2) indicates unknown."
    ::= { prtInputEntry 4 }

prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "This object provides the value of the declared dimension, in
        the cross feed direction, of the media that is (or, if empty,
        was or will be) in this input sub-unit.  The cross  feed
        direction is ninety degrees relative to the feed direction
        associated with this sub-unit. This dimension is measured in
        input sub-unit dimensional units (prtInputDimUnit).  If this
        input sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests. Otherwise, the value may be changed. The value (-1)
        means other and specifically means that this sub-unit places
        no restriction on this parameter. The value (-2) indicates
        unknown."
    ::= { prtInputEntry 5 }

prtInputMediaDimFeedDirChosen OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The printer will act as if media of the chosen dimension (in
        the feed direction) is present in this input source.  Note
        that this value will be used even if the input tray is empty.

        Feed dimension measurements
        are taken parallel relative to the feed direction
        associated with that sub-unit and are in input sub-unit
        dimensional units (DimUnit). If the printer supports the
        declared dimension, the granted dimension is the same as
        the declared dimension. If not, the granted dimension is
        set to the closest dimension that the printer supports
        when the declared dimension is set. The value (-1) means
        other and specifically indicates that this sub-unit
        places no restriction on this parameter. The value (-2)
        indicates unknown."
    ::= { prtInputEntry 6 }

prtInputMediaDimXFeedDirChosen OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The printer will act as if media of the chosen dimension (in
        the cross feed direction) is present in this input source.
        Note that this value will be used even if the input tray is
        empty.  The cross feed direction is ninety degrees relative
        to the feed direction associated with this sub-unit. This
        dimension is measured in input sub-unit dimensional units
        (DimUnit).  If the printer supports the declared
        dimension, the granted dimension is the same as the
        declared dimension. If not, the granted dimension is set
        to the closest dimension that the printer supports when
        the declared dimension is set. The value (-1) means other
        and specifically indicates that this sub-unit places no
        restriction on this parameter.  The value (-2) indicates
        unknown."
    ::= { prtInputEntry 7 }

prtInputCapacityUnit OBJECT-TYPE
    SYNTAX     CapacityUnit
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measurement for use in calculating and relaying
        capacity values for this input sub-unit."
    ::= { prtInputEntry 8 }

prtInputMaxCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION

        "The maximum capacity of the input sub-unit in input
        sub-unit capacity units (CapacityUnit).  There is no
        convention associated with the media itself so this value
        reflects claimed capacity. If this input sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be changed by management requests;
        otherwise, the value may be written (by a Remote
        Contol Panel or a Management Application).
        The value (-1) means other and specifically
        indicates that the sub-unit places no restrictions
        on this parameter.  The value (-2) means unknown."
    ::= { prtInputEntry 9 }

prtInputCurrentLevel OBJECT-TYPE
    SYNTAX     Integer32 --    in capacity units (CapacityUnit).
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The current capacity of the input sub-unit in input
        sub-unit capacity units (CapacityUnit). If this input
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by
        management requests; otherwise, the value may
        be written (by a Remote Contol Panel or a
        Management Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter. The value (-2) means unknown.
        The value (-3) means that the printer knows that at least one
        unit remains."
    ::= { prtInputEntry 10 }

prtInputStatus OBJECT-TYPE
    SYNTAX     SubUnitStatus
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this input sub-unit."
    ::= { prtInputEntry 11 }

prtInputMediaName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "A description of the media contained in this input sub-unit;
        This description is intended for display to a human operator.
        This description is not processed by the printer.  It is used
        to provide information not expressible in terms of the other

        media attributes (e.g. prtInputMediaDimFeedDirChosen,
        prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
        prtInputMediaType). An example would be `legal tender bond
        paper'."
    ::= { prtInputEntry 12 }

--               INPUT MEASUREMENT
--
--     _______ |                     |
--      ^      |                     |
--      |      |                     |                    |
--      |      |_ _ _ _ _ _ _ _ _ _ _| _________________  |direction
--      |      |                     |      ^             v
-- MaxCapacity |                     |      |
--      |      | Sheets left in tray | CurrentLevel
--      |      |                     |      |
--      v      |                     |      v
--     _______ +_____________________+ _______

-- The Extended Input Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtInputName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name assigned to this input sub-unit."
    ::= { prtInputEntry 13 }

prtInputVendorName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The vendor name of this input sub-unit."
    ::= { prtInputEntry 14 }

prtInputModel OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The model name of this input sub-unit."
    ::= { prtInputEntry 15 }

prtInputVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The version of this input sub-unit."
    ::= { prtInputEntry 16 }

prtInputSerialNumber OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..32))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The serial number assigned to this input sub-unit."
    ::= { prtInputEntry 17 }

prtInputDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "A free-form text description of this input
        sub-unit in the localization specified by
        prtGeneralCurrentLocalization."
    ::= { prtInputEntry 18 }

prtInputSecurity OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "Indicates if this input sub-unit has some security
        associated with it."
    ::= { prtInputEntry 19 }

-- The Input Media Group
--
-- The Input Media Group supports identification of media installed
-- or available for use on a printing device. Medium resources are
-- identified by name, and include a collection of characteristic
-- attributes that may further be used for selection and management
-- of them. The Input Media group consists of a set of optional
-- "columns" in the Input Table. In this manner, a minimally
-- conforming implementation may choose to not support reporting
-- of media resources if it cannot do so.
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtInputMediaWeight  OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The weight of the medium associated with this input
        sub-unit in grams / per meter squared. The value (-2) means
        unknown."
    ::= { prtInputEntry 20 }

prtInputMediaType OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name of the type of medium associated with this input
        sub-unit. This name need not be processed by the printer; it
        might simply be displayed to an operator. The standardized
        string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are:

        stationery       Separately cut sheets of an opaque material
        transparency     Separately cut sheets of a transparent material
        envelope         Envelopes that can be used for conventional
        mailing purposes
        envelope-plain   Envelopes that are not preprinted and have no
                         windows
        envelope-window  Envelopes that have windows for addressing
                         purposes
        continuous-long  Continuously connected sheets of an opaque
                         material connected along the long edge
        continuous-short Continuously connected sheets of an opaque
                         material connected along the short edge
        tab-stock        Media with tabs
        multi-part-form  Form medium composed of multiple layers not
                         pre-attached to one another; each sheet may be
                         drawn separately from an input source
        labels           Label stock
        multi-layer      Form medium composed of multiple layers which
                         are pre-attached to one another; e.g., for
                         use with impact printers"
    ::= { prtInputEntry 21 }

prtInputMediaColor OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name of the color of the medium associated with

        this input sub-unit using standardized string values
        from ISO 10175 (DPA) and ISO 10180 (SPDL) which are:

        other
        unknown
        white
        pink
        yellow
        buff
        goldenrod
        blue
        green
        transparent

        Implementors may add additional string values. The naming
        conventions in ISO 9070 are recommended in order to avoid
        potential name clashes."
    ::= { prtInputEntry 22 }

prtInputMediaFormParts OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The number of parts associated with the medium
         associated with this input sub-unit if the medium is a
         multi-part form.  The value (-1) means other and
         specifically indicates that the device places no
         restrictions on this parameter.  The value (-2) means
         unknown."
    ::= { prtInputEntry 23 }

-- The Output Group
--
-- Output sub-units are managed as a tabular, indexed collection of
-- possible devices capable of receiving media delivered from the
-- printing process.  Output sub-units typically have a location,
-- a type, an identifier, a set of constraints on possible media
-- sizes and potentially other characteristics, and may be capable
-- of indicating current status or capacity.
--
-- Implementation of every object in this group is mandatory.

prtOutput  OBJECT IDENTIFIER ::= { printmib 9 }

prtOutputDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write

    STATUS     current
    DESCRIPTION
        "The  value of prtOutputIndex  corresponding to the default
        output sub-unit; that is, this object selects the default
        output destination."
    ::= { prtGeneralEntry 7 }

prtOutputTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtOutputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of the devices capable of receiving media delivered
        from the printing process."
    ::= { prtOutput 2 }

prtOutputEntry OBJECT-TYPE
    SYNTAX     PrtOutputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Attributes of a device capable of receiving media delivered
        from the printing process.

        Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtOutputIndex }
    ::= { prtOutputTable 1 }

PrtOutputEntry ::= SEQUENCE {
        prtOutputIndex                    Integer32,
        prtOutputType                     INTEGER,
        prtOutputCapacityUnit             CapacityUnit,
        prtOutputMaxCapacity              Integer32,
        prtOutputRemainingCapacity        Integer32,
        prtOutputStatus                   SubUnitStatus,
        prtOutputName                     OCTET STRING,
        prtOutputVendorName               OCTET STRING,
        prtOutputModel                    OCTET STRING,
        prtOutputVersion                  OCTET STRING,
        prtOutputSerialNumber             OCTET STRING,
        prtOutputDescription              OCTET STRING,
        prtOutputSecurity                 PresentOnOff,
        prtOutputDimUnit                  MediaUnit,
        prtOutputMaxDimFeedDir            Integer32,
        prtOutputMaxDimXFeedDir           Integer32,
        prtOutputMinDimFeedDir            Integer32,
        prtOutputMinDimXFeedDir           Integer32,

        prtOutputStackingOrder            INTEGER,
        prtOutputPageDeliveryOrientation  INTEGER,
        prtOutputBursting                 PresentOnOff,
        prtOutputDecollating              PresentOnOff,
        prtOutputPageCollated             PresentOnOff,
        prtOutputOffsetStacking           PresentOnOff
}

prtOutputIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by this printer to identify this
        output sub-unit. Although these values may change due
        to a major reconfiguration of the sub-unit (e.g.  the
        addition of new output devices to the printer), values
        are expected to remain stable across successive printer
        power cycles."
    ::= { prtOutputEntry 1 }

prtOutputType OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   removableBin(3),
                   unRemovableBin(4),
                   continuousRollDevice(5),
                   mailBox(6),
                   continuousFanFold(7)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of technology supported by this output sub-unit."
    ::= { prtOutputEntry 2 }

prtOutputCapacityUnit OBJECT-TYPE
    SYNTAX     CapacityUnit
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measurement for use in calculating and relaying
        capacity values for this output sub-unit."
    ::= { prtOutputEntry 3 }

prtOutputMaxCapacity OBJECT-TYPE

    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The maximum capacity of this output sub-unit in output
        sub-unit capacity units (CapacityUnit). There is no
        convention associated with the media itself so this value
        essentially reflects claimed capacity. If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests; otherwise, the value may be written
        (by a Remote Contol Panel or a Management Application).
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown."
    ::= { prtOutputEntry 4 }

prtOutputRemainingCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The remaining capacity of the possible output sub-unit
        capacity in output sub-unit capacity units (CapacityUnit)
        of this output sub-unit. If this output sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be modified by management requests;
        otherwise, the value may be written (by
        a Remote Contol Panel or a Management
        Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter.  The value (-2) means
        unknown.  The value (-3) means that the printer knows that
        there remains capacity for at least one unit."
    ::= { prtOutputEntry 5 }

prtOutputStatus OBJECT-TYPE
    SYNTAX     SubUnitStatus
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this output sub-unit."
    ::= { prtOutputEntry 6 }

--               OUTPUT MEASUREMENT
--
--     _______ |                     | _______
--      ^      |                     |      ^
--      |      |                     |      |
--      |      |                     | RemainingCapacity
-- MaxCapacity |                     |      |
--      |      |                     |      v               ^
--      |      |_ _ _ _ _ _ _ _ _ _ _| ___________________  |direction
--      |      |                     |                      |
--      |      |  Sheets in output   |
--      v      |                     |
--     _______ +_____________________+

-- The Extended Output Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name assigned to this output sub-unit."
    ::= { prtOutputEntry 7 }

prtOutputVendorName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The vendor name of this output sub-unit."
    ::= { prtOutputEntry 8 }

prtOutputModel OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The name assigned to this output sub-unit."
    ::= { prtOutputEntry 9 }

prtOutputVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION

        "The version of this output sub-unit."
    ::= { prtOutputEntry 10 }

prtOutputSerialNumber OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The serial number assigned to this output sub-unit."
    ::= { prtOutputEntry 11 }

prtOutputDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "  A free-form text description of this output sub-unit in the
        localization specified by prtGeneralCurrentLocalization."
    ::= { prtOutputEntry 12 }

prtOutputSecurity OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "Indicates if this output sub-unit has some security associated
        with it and if that security is enabled or not."
    ::= { prtOutputEntry 13 }

-- The Output Dimensions Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputDimUnit OBJECT-TYPE
    SYNTAX     MediaUnit
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measurement for use in calculating and relaying
        dimensional values for this output sub-unit."
    ::= { prtOutputEntry 14 }

prtOutputMaxDimFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION

        "The maximum dimensions supported by this output sub-unit
        for measurements taken parallel relative to the feed
        direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 15 }

prtOutputMaxDimXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The maximum dimensions supported by this output sub-unit
        for measurements taken ninety degrees relative to the
        feed direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 16 }

prtOutputMinDimFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The minimum dimensions supported by this output sub-unit
        for measurements taken parallel relative to the feed
        direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit).  If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 17 }

prtOutputMinDimXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The minimum dimensions supported by this output sub-unit
        for measurements taken ninety degrees relative to the
        feed direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with

        management protocol operations."
    ::= { prtOutputEntry 18 }

-- The Output Features Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputStackingOrder OBJECT-TYPE
    --  This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   unknown(2),
                   firstToLast(3),
                   lastToFirst(4)
               }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The current state of the stacking order for the
        associated output sub-unit. `FirstToLast' means
        that as pages are output the front of the next page is
        placed against the back of the previous page.
        `LasttoFirst' means that as pages are output the back
        of the next page is placed against the front of the
        previous page."
    ::= { prtOutputEntry 19 }

prtOutputPageDeliveryOrientation OBJECT-TYPE
    --   This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   faceUp(3),
                   faceDown(4)
               }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The reading surface that will be `up' when pages are
        delivered to the associated output sub-unit. Values are
        Face-Up and Face-Down. (Note: interpretation of these
        values is in general context-dependent based on locale;
        presentation of these values to an end-user should be
        normalized to the expectations of the user)."
    ::= { prtOutputEntry 20 }

prtOutputBursting OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current

    DESCRIPTION
        "This object indicates that the outputing sub-unit
        supports bursting, and if so, whether the feature is enabled.
        Bursting is the process by which continuous media is separated
        into individual sheets, typically by bursting along pre-formed
        perforations."
    ::= { prtOutputEntry 21 }

prtOutputDecollating OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "This object indicates that the output supports
        supports decollating, and if so, whether the feature
        is enabled. Decollating is the process by which the
        individual parts within a multi-part form are separated
        and sorted into separate stacks for each part."
    ::= { prtOutputEntry 22 }

prtOutputPageCollated OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "This object indicates that the output sub-unit
        supports page collation, and if so, whether the feature is
        enabled."
    ::= { prtOutputEntry 23 }

prtOutputOffsetStacking OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "This object indicates that the output supports
        supports offset stacking, and if so, whether the feature is
        enabled."
    ::= { prtOutputEntry 24 }

-- The Marker Group
--
-- A marker is the mechanism that produces marks on the print media.  The
-- marker sub-units and their associated supplies are represented by the
-- Marker Group in the model.  A printer can contain one or more marking
-- mechanisms.  Some examples of multiple marker sub-units are: a printer
-- with separate markers for normal and magnetic ink or an imagesetter
-- that can output to both a proofing device and final film. Each marking

-- device can have its own set of  characteristics associated with it,
-- such as marking technology and resolution.
--
-- Implementation of every object in this group is mandatory.

prtMarker OBJECT IDENTIFIER ::= { printmib 10 }

prtMarkerDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The value of prtMarkerIndex  corresponding to the
        default markersub-unit; that is, this object selects the
        default marker."
    ::= { prtGeneralEntry 8 }

-- The printable area margins as listed below define an area of the print
-- media which is guaranteed to be printable for all combinations of
-- input, media paths, and interpreters for this marker.

prtMarkerTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtMarker 2 }

prtMarkerEntry OBJECT-TYPE
    SYNTAX     PrtMarkerEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtMarkerIndex }
    ::= { prtMarkerTable 1 }

PrtMarkerEntry ::= SEQUENCE {
        prtMarkerIndex                  Integer32,
        prtMarkerMarkTech               INTEGER,
        prtMarkerCounterUnit            INTEGER,
        prtMarkerLifeCount              Counter32,
        prtMarkerPowerOnCount           Counter32,
        prtMarkerProcessColorants       Integer32,
        prtMarkerSpotColorants          Integer32,

        prtMarkerAddressabilityUnit     INTEGER,
        prtMarkerAddressabilityFeedDir  Integer32,
        prtMarkerAddressabilityXFeedDir Integer32,
        prtMarkerNorthMargin            Integer32,
        prtMarkerSouthMargin            Integer32,
        prtMarkerWestMargin             Integer32,
        prtMarkerEastMargin             Integer32,
        prtMarkerStatus                 SubUnitStatus
}

prtMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this marking
        SubUnitStatus.  Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new marking
        sub-units to the printer), values are expected to remain
        stable across successive printer power cycles."
    ::= { prtMarkerEntry 1 }

prtMarkerMarkTech OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   electrophotographicLED(3),
                   electrophotographicLaser(4),
                   electrophotographicOther(5),
                   impactMovingHeadDotMatrix9pin(6),
                   impactMovingHeadDotMatrix24pin(7),
                   impactMovingHeadDotMatrixOther(8),
                   impactMovingHeadFullyFormed(9),
                   impactBand(10),
                   impactOther(11),
                   inkjetAqueous(12),
                   inkjetSolid(13),
                   inkjetOther(14),
                   pen(15),
                   thermalTransfer(16),
                   thermalSensitive(17),
                   thermalDiffusion(18),
                   thermalOther(19),
                   electroerosion(20),
                   electrostatic(21),
                   photographicMicrofiche(22),

                   photographicImagesetter(23),
                   photographicOther(24),
                   ionDeposition(25),
                   eBeam(26),
                   typesetter(27)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of marking technology used for this marking sub-unit."
    ::= { prtMarkerEntry 2 }

prtMarkerCounterUnit OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   tenThousandthsOfInches(3),  -- .0001
                   micrometers(4),
                   characters(5),
                   lines(6),
                   impressions(7),
                   sheets(8),
                   dotRow(9),
                   hours(11),
                   feet(16),
                   meters(17)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit that will be used by the printer when reporting
        counter values for this marking sub-unit.  The
        time units of measure are provided for a device like a
        strip recorder that does not or cannot track the physical
        dimensions of the media and does not use characters,
        lines or sheets."
    ::= { prtMarkerEntry 3}

prtMarkerLifeCount OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The count of the number of units of measure counted during
        the life of printer using units of measure as specified by
        CounterUnit."
    ::= { prtMarkerEntry 4 }

prtMarkerPowerOnCount OBJECT-TYPE

    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The count of the number of units of measure counted since the
        equipment was most recently powered on using units of measure as
        specified by CounterUnit."
    ::= { prtMarkerEntry 5 }

prtMarkerProcessColorants OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of process colors supported by this marker.  A
        process color of 1 implies monochrome.  The value of this
        object and SpotColorants cannot both be 0.  Must be 0 or
        greater."
    ::= { prtMarkerEntry 6 }

prtMarkerSpotColorants OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of spot colors supported by this marker.  The
        value of this object and ProcessColorants cannot
        both be 0.  Must be 0 or greater."
    ::= { prtMarkerEntry 7 }

prtMarkerAddressabilityUnit OBJECT-TYPE
    --   This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   tenThousandthsOfInches(3),  -- .0001
                   micrometers(4)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measure of distances."
    ::= { prtMarkerEntry 8 }

prtMarkerAddressabilityFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The  number of addressable marking positions in the feed

        direction per 10000 units of measure specified by
        AddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'."
    ::= { prtMarkerEntry 9 }

prtMarkerAddressabilityXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of addressable marking positions in the cross
        feed direction in 10000 units of measure specified by
        AddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'."
    ::= { prtMarkerEntry 10 }

prtMarkerNorthMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The margin, in units identified by AddressabilityUnit,
        from the leading edge of the medium as the medium flows
        throught the marking engine with the side to be imaged
        facing the observer. The leading edge is the North edge
        and the other edges are defined by the normal compass
        layout of  directions with the compass facing the
        observer.  Printing within the area bounded by all four
        margins is guaranteed for all interpreters.   The value
        (-2) means unknown."
    ::= { prtMarkerEntry 11 }

prtMarkerSouthMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The margin from the South edge  (see NorthMargin)
        of the medium in units identified by
        AddressabilityUnit.  Printing within the area bounded by
        all four margins  is guaranteed for all interpreters.
        The value (-2) means unknown."
    ::= { prtMarkerEntry 12 }

prtMarkerWestMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current

    DESCRIPTION
        "The margin from the West edge (see NorthMargin) of the
        medium in units identified by AddressabilityUnit.
        Printing within the area bouned by all four margins is
        guaranteed for all interpreters.   The value (-2) means
        unknown."
    ::= { prtMarkerEntry 13 }

prtMarkerEastMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The margin from the East edge (see NorthMargin) of the
        medium in units identified by AddressabilityUnit.
        Printing within the area bounded by all four margins is
        guaranteed for all interpreters. The value (-2) means
        unknown."
    ::= { prtMarkerEntry 14 }

prtMarkerStatus OBJECT-TYPE
    SYNTAX     SubUnitStatus
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this marker sub-unit."
        ::= { prtMarkerEntry 15 }

-- The Marker Supplies Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }

prtMarkerSuppliesTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerSuppliesEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of the marker supplies available on this printer."
    ::= { prtMarkerSupplies 1 }

prtMarkerSuppliesEntry OBJECT-TYPE
    SYNTAX     PrtMarkerSuppliesEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION

        "Attributes of a marker supply.

        Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtMarkerSuppliesIndex }
    ::= { prtMarkerSuppliesTable 1 }

PrtMarkerSuppliesEntry ::= SEQUENCE {
        prtMarkerSuppliesIndex          Integer32,
        prtMarkerSuppliesMarkerIndex    Integer32,
        prtMarkerSuppliesColorantIndex  Integer32,
        prtMarkerSuppliesClass          INTEGER,
        prtMarkerSuppliesType           INTEGER,
        prtMarkerSuppliesDescription    OCTET STRING,
        prtMarkerSuppliesSupplyUnit     INTEGER,
        prtMarkerSuppliesMaxCapacity    Integer32,
        prtMarkerSuppliesLevel          Integer32
}

prtMarkerSuppliesIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this marker
        supply.  Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new marker
        supplies to the printer), values are expected to remain stable
        across successive printer power cycles."
    ::= { prtMarkerSuppliesEntry 1 }

prtMarkerSuppliesMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of prtMarkerIndex corresponding to the
        marking sub-unit with which this marker supply
        sub-unit is associated."
    ::= { prtMarkerSuppliesEntry 2 }

prtMarkerSuppliesColorantIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of prtMarkerColorantIndex

        corresponding to the colorant with which this
        marker supply sub-unit is associated.  This value
        shall be 0 if there is no colorant table."
    ::= { prtMarkerSuppliesEntry 3 }

prtMarkerSuppliesClass OBJECT-TYPE
    --  This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   supplyThatIsConsumed(3),
                   receptacleThatIsFilled(4)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "Indicates whether this supply entity represents a supply
        container that is consumed or a receptacle that is filled."
    ::= { prtMarkerSuppliesEntry 4 }

prtMarkerSuppliesType OBJECT-TYPE
    --   This value is a type 3 enumeration
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   toner(3),
                   wasteToner(4),
                   ink(5),
                   inkCartridge(6),
                   inkRibbon(7),
                   wasteInk(8),
                   opc(9),
                   developer(10),
                   fuserOil(11),
                   solidWax(12),
                   ribbonWax(13),
                   wasteWax(14)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of this supply."
    ::= { prtMarkerSuppliesEntry 5 }

prtMarkerSuppliesDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION

        "The description of this supply container/receptacle in the
        localization specified by prtGeneralCurrentLocalization."
    ::= { prtMarkerSuppliesEntry 6 }

prtMarkerSuppliesSupplyUnit OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   tenThousandthsOfInches(3),  -- .0001
                   micrometers(4),
                   thousandthsOfOunces(12),
                   tenthsOfGrams(13),
                   hundrethsOfFluidOunces(14),
                   tenthsOfMilliliters(15)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "Unit of this marker supply container/receptacle."
    ::= { prtMarkerSuppliesEntry 7 }

prtMarkerSuppliesMaxCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The maximum capacity of this supply container/receptacle
        expressed in SupplyUnit. If this supply
        container/receptacle can reliably sense this value, the
        value is sensed by the printer and is read-only;
        otherwise, the value may be written (by a Remote Contol
        Panel or a Management Application). The value (-1) means
        other and specifically indicates that the sub-unit places
        no restrictions on this parameter. The value (-2) means
        unknown."
    ::= { prtMarkerSuppliesEntry 8 }

prtMarkerSuppliesLevel OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The current level if this supply is a container; the
        remaining space if this supply is a receptacle. If this
        supply container/receptacle can reliably sense this
        value, the value is sensed by the printer and is
        read-only; otherwise, the value may be written (by a
        Remote Contol Panel or a Management Application). The
        value (-1) means other and specifically indicates that

        the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown.  A value of (-3) means that the
        printer knows that there is some supply/remaining space,
        respectively."
    ::= { prtMarkerSuppliesEntry 9 }

-- The Marker Colorant Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }

prtMarkerColorantTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerColorantEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of all of the colorants available on the printer."
    ::= { prtMarkerColorant 1 }

prtMarkerColorantEntry OBJECT-TYPE
    SYNTAX     PrtMarkerColorantEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Attributes of a colorant available on the printer.

        Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX { hrDeviceIndex, prtMarkerColorantIndex }
    ::= { prtMarkerColorantTable 1 }

PrtMarkerColorantEntry ::= SEQUENCE {
        prtMarkerColorantIndex          Integer32,
        prtMarkerColorantMarkerIndex    Integer32,
        prtMarkerColorantRole           INTEGER,
        prtMarkerColorantValue          OCTET STRING,
        prtMarkerColorantTonality       Integer32
}

prtMarkerColorantIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this colorant.
        Although these values may change due to a major

        reconfiguration of the device (e.g. the addition of new
        colorants to the printer), values are expected to remain
        stable across successive printer power cycles."
    ::= { prtMarkerColorantEntry 1 }

prtMarkerColorantMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of prtMarkerIndex corresponding to the
        marker sub-unit with which this colorant entry is
        associated."
    ::= { prtMarkerColorantEntry 2 }

prtMarkerColorantRole OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     INTEGER { --  Colorant Role
                   other(1),
                   process(3),
                   spot(4)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The role played by this colorant."
    ::= { prtMarkerColorantEntry 3 }

prtMarkerColorantValue OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The name of the color of this The name of the color of this
        colorant using standardized string names from ISO 10175 (DPA)
        and ISO 10180 (SPDL) which are:
          other
          unknown
          white
          red
          green
          blue
          cyan
          magenta
          yellow
          black
        Implementors may add additional string values. The naming
        conventions in ISO 9070 are recommended in order to avoid

        potential name clashes"
    ::= { prtMarkerColorantEntry 4 }

prtMarkerColorantTonality OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The distinct levels of tonality realizable by a marking
        sub-unit when using this colorant.  This value does not
        include the number of levels of tonal difference that an
        interpreter can obtain by techniques such as half toning.
        This value must be at least 2."
    ::= { prtMarkerColorantEntry 5 }

-- The Media Path Group
--
-- The media paths encompass the mechanisms in the printer that move the
-- media through the printer and connect all other media related sub-
-- units: inputs, outputs, markers and finishers. A printer contains one
-- or more media paths. These are represented by the Media Path Group in
-- the model. The Media Path group has some attributes that apply to all
-- paths plus a table of the separate media paths.

prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }

prtMediaPathDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The value of prtMediaPathIndex corresponding to
        the default media path; that is, the selection of the
        default media path."
    ::= { prtGeneralEntry 9 }

prtMediaPathTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMediaPathEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtMediaPath 4 }

prtMediaPathEntry OBJECT-TYPE
    SYNTAX     PrtMediaPathEntry
    MAX-ACCESS not-accessible
    STATUS     current

    DESCRIPTION
        "Entries may exist in the table for each device
        index who's device type is `printer'."
    INDEX  { hrDeviceIndex, prtMediaPathIndex }
    ::= { prtMediaPathTable 1 }

PrtMediaPathEntry ::= SEQUENCE {
    prtMediaPathIndex               Integer32,
    prtMediaPathMaxSpeedPrintUnit   INTEGER,
    prtMediaPathMediaSizeUnit       MediaUnit,
    prtMediaPathMaxSpeed            Integer32,
    prtMediaPathMaxMediaFeedDir     Integer32,
    prtMediaPathMaxMediaXFeedDir    Integer32,
    prtMediaPathMinMediaFeedDir     Integer32,
    prtMediaPathMinMediaXFeedDir    Integer32,
    prtMediaPathType                INTEGER,
    prtMediaPathDescription         OCTET STRING,
    prtMediaPathStatus              SubUnitStatus
}

prtMediaPathIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this media
        path. Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new
        media paths to the printer), values are expected to remain
        stable across successive printer power
        cycles."
    ::= { prtMediaPathEntry 1 }

prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   tenThousandthsOfInchesPerHour(3),   -- .0001/hour
                   micrometersPerHour(4),
                   charactersPerHour(5),
                   linesPerHour(6),
                   impressionsPerHour(7),
                   sheetsPerHour(8),
                   dotRowPerHour(9),
                   feetPerHour(16),
                   metersPerHour(17)
               }
    MAX-ACCESS read-only

    STATUS     current
    DESCRIPTION
        "The unit of measure used in specifying the speed of all media
        paths in the printer."
    ::= { prtMediaPathEntry 2 }

prtMediaPathMediaSizeUnit OBJECT-TYPE
    SYNTAX     MediaUnit
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The units of